Transformer capacity: KVA
No-load loss P0 (W): 390
Load loss Pk (W): 3330
Voltage level: 15 (22) /0.4
Frequency: 50HZ
QUANG ANH – supply transformers THIBIDI products with capacity up to 5000kva, voltage 15 – 22kv.
The THIBIDI 320KVA application machine has the special features of easy installation, long service life, simple operation, and no maintenance.
THIBIDI 320KVA transformer is widely used for installation, in factories, roofing houses, apartment buildings, restaurants, hospitals, airports …..
If you have a need to build a 320KVA transformer package, please contact QUANG ANH for advice & quotation.
I/Minimum Energy Efficiency
The minimum energy efficiency of a transformer is an important parameter that any manufacturer or importer must know.
1) Definition:
Energy efficiency is the ratio in % between the active output power and the input active power of the distribution transformer.
2) Calculation method (formula):
![]()
In there:
E 50%: Efficiency in % of the transformer at 50% load and at a power factor of 1.
S: Transformer rated power, kVA.
Pk: Transformer load loss, kW.
Po: Transformer no-load loss, kW.
3) Example:
THIBIDI transformer 250kVA – 35/0.4kV:
S= 250kVA
Pk= 3.2kW
Po= 0.64kW
![]()
THIBIDI transformer 1800kVA – 22/0.4kV:
S= 1800kVA
Pk= 17.8kW
Po= 2.5kW
![]()
4) Measures for transformers to achieve “Minimum Energy Efficiency”:
a. Numerical measures:
+ Reduce Pk,
+ Reduce Po.
b. Action measures:
+ Standard design (TCVN 6306:2006),
+ Using standard materials (copper wire, silicon corrugated iron),
+ Advanced technology equipment (corrugated iron cutting machine, wire winding machine),
+ Good construction control.
II/Service
1. Service statement:
Quang Anh Electrical Construction is the first-class agent of transformer brands in Vietnam market such as THIBIDI, AGE, SHIHLIN, HEM, HBA, GPBA, ABB, HUYNDAI, ATELEC, EMC, EEMC, SANAKY and other products. relate to. Transformer capacity from 1P 15KVA, 25KVA, 37.5KVA, 50KVA, 75KVA 100KVA. Up to 3P 100KVA, 160KVA, 180KVA, 250KVA, 320KVA, 400KVA, 560KVA, 630KVA, 750KVA, 800KVA, 1000KVA, 1250KVA, 1500KVA, 1600KVA, 2000KVA, 2500KVA, 4000KVA, 5000KVA.
We serve all customers throughout the territory of Vietnam.
2. Buying guide:
– Customers choose the products they need at the product group on the website
– To make a purchase, please contact the address or phone number on the website
– For business customers, please provide information for us to issue sales invoices.
3. Payment:
– With orders more than or equal to 20,000,000 VND. Please pay via bank from your bank account to our company’s bank
4. Delivery and shipping time:
– Available goods: delivered within 15 to 20 days within the whole territory of Vietnam.
– Unavailable goods: Due to the characteristics of industrial products, there are some types of goods that are not available in stock. Order time from 1 week or more depending on the product.
– Free delivery within Ho Chi Minh city
5. Warranty period:
– Item supplied is guaranteed 100% new.
– The warranty period is applied according to the policy of the manufacturer manufacturer product, normally 12 months.
![]()
Quang Anh CE Co.,LTD
Website: https://thicongtrambienap.com
Office: 2nd Floor, I2 Building, No. 236/26 Dien Bien Phu, Ward 17, Binh Thanh District, Ho Chi Minh City
Hotline: 0919758191
Email: sales@thicongtrambieap.com
Tax code: 0316365712
Tính nhanh giá trạm biến áp
Chọn công suất và chiều dài tuyến để xem giá tham khảo cùng thông số điện.
Gửi yêu cầu báo giá theo thiết kế
Gửi thông tin công trình, BOQ hoặc bản vẽ để nhận báo giá chính thức. Các trường có * là bắt buộc.
Phạm vi báo giá
Áp dụng cho một trạm mua điện EVN, máy dầu 22/0,4 kV (máy một pha: 12,7/0,23 kV), TU/TI trung thế do EVN cấp. Giá gồm thiết bị theo cấu hình, lắp đặt, tiếp địa, liên kết máy–CB tổng, hồ sơ thiết kế–đấu nối và phối hợp thí nghiệm, nghiệm thu điện lực.
Kios, trụ thép hợp bộ và trạm trong nhà có tủ trung thế cùng đoạn cáp ngầm theo thông tin đã nhập. Các kiểu ngoài trời dùng phương án bảo vệ tương ứng; sơ đồ cuối cùng cần phù hợp yêu cầu đấu nối tại công trình.
Chưa gồm VAT, cáp từ tủ trạm đến MSB/phụ tải, hotline, cuộn kháng lọc hài, nền yếu/cọc đặc biệt, đất và PCCC đặc thù. Tuyến ngầm tính theo điều kiện thi công thông thường, chưa gồm khoan qua đường hoặc hoàn trả đặc biệt.
Giá dùng để tham khảo đầu tư. Báo giá chính thức được xác nhận sau khảo sát và thống nhất cấu hình. Thông số điện là lựa chọn sơ bộ, cần kiểm tra theo thiết kế trước khi thi công.
Dải công suất và điều kiện áp dụng
Danh mục là phạm vi tiếp nhận yêu cầu của công cụ, không phải giới hạn công suất chung của TCVN. Trạm treo một máy: 15–100 kVA; bộ ba máy: 3×15–3×100 kVA. Giàn: 100–630 kVA. Trụ thép: 100–630 kVA; 750/800 kVA cần xác nhận thiết kế và chấp thuận tại địa phương. Nền/kios/phòng: danh mục 50–10.000 kVA, không có nghĩa mọi cấu hình đều có giá trọn gói hoặc cùng kết cấu.
Tham khảo QĐ 1299/QĐ-EVN ngày 03/11/2017, Tập 1, mục 3.3–3.4; kiểm tra văn bản hiện hành của điện lực quản lý trước khi triển khai. Kios phải phù hợp định mức/thử nghiệm của nhà chế tạo (IEC 62271-202); phòng/nền phải đáp ứng bố trí, thông gió, kết cấu và PCCC của dự án. Công suất trạm nhiều máy phải tách số máy và công suất mỗi máy.
Công cụ do QuangAnhcons phát triển · © 2026 QuangAnhcons. Mã nguồn theo GPL-2.0-or-later; tiêu chuẩn và dữ liệu hãng thuộc chủ sở hữu tương ứng.